Why is my Heating System not Working?
Home heating systems in the Gresham and surrounding areas are an essential part of keeping you and your family comfortable. If you are noticing your furnace blowing cold air or not turning on at all after your turn heat on the thermostat, we are going to answer some of the questions as to why this happens.

What causes a Heating System to stop Working?
There are many things that will cause a furnace to stop working during the cold winter months. Some common problems include a dirty air filter, loss of flame, safety switches, failed blower motor or a failed control board to name a few.
Heating System not Working Due to Air Filter
Air Filters can cause a heating system to stop working. As an air filter gets dirty from normal heating operation, the air filter will start to become more and more restrictive. When an air filter gets dirty and starts to restrict airflow the blower motor starts to struggle. Its like having the furnace pull air through a straw. This lack of air causes the blower motor to run outside of its static pressure design and causes the motor to start over heating and pulling more amps. This will cause the blower motor to fail prematurely due to the higher stress of trying to pull air through the furnace and the constant excessive heat. We will go into more detail on blower motor failure later in this post.
The second side effect of having a dirty air filter is the furnace itself starting to over heat. When the burners come on on a gas furnace and start heating up the heat exchanger, the control board will initiate a call for the blower motor to turn on and start moving air across the heat exchanger. This air absorbs heat from the heat exchanger and carries it through your air ducts into the rooms and conditioned spaces of your home. If the blower motor cannot supply enough air across the heat exchanger to absorb heat, the heat exchanger itself will begin to over heat, causing the furnace to trip the High Limit safety switch. This safety switch trips once a heat exchanger exceeds the rated temperature limit for your furnace. The safety switch trips, telling the control board to shut down the gas and run the blower only to cool down the furnace.
Air filter replacements at regular intervals will help prevent this issue. We recommend replacing 1" thick filters once a month and 4" thick filters once every 3 to 6 months. Air filters come in different MERV ratings and efficiencies so care must be taken when selecting a higher MERV rated filter. Air filters will have a filter pressure drop chart printed on them from the filter manufacturer, showing how restrictive the air filter is. Comparing this chart to your existing filter during replacement will help you determine how restrictive a higher rated air filter is compared to your existing filter.
A&B Air Solutions LLC offers professional heating service in Gresham and the surrounding areas. If you are in need of an air filter recommendation or suggestion, feel free to give us a call!
Loss of Flame Will Cause a Heating system to Stop Working
Loss of flame will cause a heating system to stop working. A gas furnace has a burner compartment that houses the inducer motor, gas valve, burner assembly and Heat exchanger. The furnace also has an array of safety switches to help ensure that once the gas valve opens and the burners are lit, that the flame is performing in a safe and controlled manner. One of these safety sensors is known as the flame sensor. The job of the flame sensor is to send a DC micro amp current back to the control board to prove that the flame has ignited.
The flame sensor accomplishes this by receiving a 120V signal from the control board and sending the signal back through the flames via a DC micro amp current. The hot surface igniter is typically located on the other side of the burner assembly. As the hot surface igniter lights the end burner, the burners all light in sequence within a second across to the flame sensor. Once the flame is lit, the sensor then is able to send the micro amp current through the flames, through the burner assembly and traveling through a ground wire back to the control board. If the hot surface igniter fails, the burners are misaligned, or there are other issues with the gas valve or fuel gas supply and the burners fail to light. The control board will quickly turn the gas valve off to prevent filling the compartment with natural gas and try again. After 3 consecutive tries the control board will lock the furnace out until a qualified technician can service and diagnose the issue. The control board will also flash an error code for a loss of flame status.
If this is a suspected issue you are having, we highly recommend calling A&B Air Solutions LLC and scheduling a diagnostics appointment to have our professional technician perform a diagnostics on your heating system.
Furnace Safety Switches
Your furnace has an array of safety switches built into the controls to insure safe operation. Some of these safety switches insure your flame ignites properly, while others insure the flame is routed into the heat exchanger tubes without rolling out into the burner compartment. This helps your heating system insure a safe burner operation.
Your furnace also has a High Limit switch that monitors your heat exchanger temperature, a vacuum switch that insures proper inducer motor operation and venting, as well as a thermal safety switch on the blower motor housing to monitor furnace temperature.
In Gresham, a gas furnace is the most common heating system. Troutdale also uses mostly a gas furnace for heat with some electric heat pumps. These gas furnaces monitor all safety switches to insure safe operation. If any safety switch trips, the control board will either try to cool the furnace back down or completely lock out the heating system.
If you're living in Gresham and your heating system is not turning on, give us a call or book us online for your Furnace diagnostics appointment. Our professional and friendly techs will help diagnose the issue.
Blower Motor Failure
One of the main integral parts of your central heating system is the blower that moves air through your furnace and the air ducts. This blower motor is sized and rated based on your furnace size. Modern blower motors are known as ECM motors. These motors are 3 phase motors with an Electronic Control Module bolted on the back. ECM motors are great for giving your heating system an array of speed options to help control airflow through your home. The draw back to this motor design is Heat. If the air ducts are undersized or the air filter gets dirty, the ECM will begin to overheat. If the air flow condition is not corrected the ECM will fail prematurely, causing blower motor failure and a furnace over heat condition.
Variable Speed Motors are another blower motor vastly used in the Gresham, Troutdale, Portland, Boring, Damascus and Sandy market. Variable Speed Motors do exactly what their name implies, they will ramp their speed up or down based on the programmed algorithm in the control board. These motors can actually perform under more sever air flow restrictions due to their high threshold for static pressure but these motors also suffer from the same condition. If run under sever conditions, the motor and ECM controller will run hotter and will cause premature failure of the blower motor.
If your blower motor is failing every few years then static pressure testing and air duct correction may be the solution to help prolong your blower motor life. Give A&B Air Solutions LLC a call or book us online for a diagnostics appointment if this may be the case for your heating system.
Control Board Failure
In the Gresham and Troutdale area control boards are in almost every single heating system type, from Gas Furnaces to Electric Furnace and Heat Pumps. Control boards are like the Mother board on your PC. They tie everything together and run the programs installed on them from the factory to help insure an efficient and proper operation. Control boards monitor all safety systems during heating mode, as well as give signals for gas valve, inducer motor and blower motor operation.
Control board failure is another common failure in the Gresham area. Sometimes all the systems on your gas furnace are working correctly and the control board itself is the failed part. A professional technician would diagnose this issue and if the control board is found at fault, the board will be replaced.
If a control board replacement is required for your Furnace, A&B Air Solutions LLC will always offer an OEM replacement. If OEM is not available there is an array of universal control boards that can be used to replace the factory board. Universal control boards are a great option as they cover a vast variety of Furnace models and manufacturers but an OEM board is always preferred as this board is specifically designed by the manufacturer for your specific furnace.
Conclusion
Your heating system is an essential part of your home and requires preventive maintenance and safety checks to help prevent failures and insure safe operation. There may be other failures not listed above. The failures listed above are just some of the more common issues our techs see in the Gresham and Portland area.
Your heating system can have failures outside of what is covered here. If your furnace is not working or blowing cold air. Give A&B Air Solutions LLC a call or book us online for your Furnace Diagnostics appointment or Preventive Maintenance.